Sign In | Join Free | My ccnmag.com |
|
Brand Name : SIEMENS
Model Number : 6ES7518-4AP00-3AB0
Certification : CE
Place of Origin : Germany
MOQ : 1
Price : USD
Payment Terms : L/C, T/T
Supply Ability : 100
Delivery Time : 10-12Days
Packaging Details : 15,10 x 15,40 x 4,60
Cpu Type : S7-1511C
Weight : 0.8 kg
Dimensions : 130 x 125 x 130 mm
Power Supply : 24 V DC
Number Of Digital Inputs : 16
Protection Rating : IP20
Operating Temperature : -20 to 60 degrees Celsius
Memory : 2 MB
Programming Language : STEP 7 (TIA Portal)
Certifications : CE, UL, CSA
Communication Interfaces : PROFINET, PROFIBUS, Ethernet, USB
Number Of Analog Outputs : 2
Number Of Analog Inputs : 4
Number Of Digital Outputs : 16
SIEMENS 6ES7518-4AP00-3AB0 PROFINET RT, 3RD INTERFACE: PROFINET BASIC SERVICES, 4TH INTERFACE: PROFIBUS
SIEMENS 6ES7518-4AP00-3AB0 MODULE INFORMATION
SIEMENS 6ES7518-4AP00-3AB0 IS A MODULAR CONTROLLER FROM THE SIMATIC S7-1500 SERIES. It has the following characteristics:
The first interface: P ROFINET RT (Real Time) for real-time communication.
The second interface: PROFINET IRT (Isolated Real Time) with cross-border swapping for isolation and increased reliability of real-time communication.
The third interface: PROFINET basic services, which are used to provide additional network functions.
The fourth interface, PROFIBUS, is used to communicate with existing PROFIBUS network devices.
Performance: 1 ns bit performance, meaning it is capable of handling data rates up to 1 Gbit/s.
Memory card requirements: Use SIMATIC Memory Card, a storage medium for storing programs and data.
The module is suitable for applications that require simultaneous support for several industrial communication protocols, such as the integration of PROFINET and PROFIBUS devices in a single system, or where high-performance real-time communication is required
General information | ||
Product type designation | CPU 1518-4 PN/DP ODK | |
HW functional status | FS10 | |
Firmware version | V2.9 | |
Product function | ||
● I&M data | Yes; I&M0 to I&M3 | |
● Isochronous mode | Yes; Distributed and central; with minimum OB 6x cycle of 125 µs (distributed) and 1 ms (central) | |
Engineering with | ||
● STEP 7 TIA Portal configurable/integrated from version | V17 (FW V2.9) / V14 (FW V2.0) or higher | |
Configuration control | ||
via dataset | Yes | |
Display | ||
Screen diagonal [cm] | 6.1 cm | |
Control elements | ||
Number of keys | 6 | |
Mode selector switch | 1 | |
Supply voltage | ||
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | |
Reverse polarity protection | Yes | |
Mains buffering | ||
● Mains/voltage failure stored energy time | 5 ms | |
Input current | ||
Current consumption (rated value) | 1.55 A | |
Inrush current, max. | 2.4 A; Rated value | |
I²t | 0.02 A²·s | |
Power | ||
Infeed power to the backplane bus | 12 W | |
Power consumption from the backplane bus (balanced) | 30 W | |
Power loss | ||
Power loss, typ. | 24 W | |
Memory | ||
Number of slots for SIMATIC memory card | 1 | |
SIMATIC memory card required | Yes | |
Work memory | ||
● integrated (for program) | 6 Mbyte | |
● integrated (for data) | 60 Mbyte | |
● integrated (for CPU function library of CPU Runtime) | 50 Mbyte; Note: The "CPU function library of the CPU" are C/C++ blocks for the user program that were created using the SIMATIC ODK 1500S or Target 1500S. | |
Load memory | ||
● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte | |
Backup | ||
● maintenance-free | Yes | |
CPU processing times | ||
for bit operations, typ. | 1 ns | |
for word operations, typ. | 2 ns | |
for fixed point arithmetic, typ. | 2 ns | |
for floating point arithmetic, typ. | 6 ns | |
CPU-blocks | ||
Number of elements (total) | 20 000; Blocks (OB, FB, FC, DB) and UDTs | |
DB | ||
● Number range | 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 | |
● Size, max. | 16 Mbyte; For DBs with absolute addressing, the max. size is 64 KB | |
FB | ||
● Number range | 0 ... 65 535 | |
● Size, max. | 1 Mbyte | |
FC | ||
● Number range | 0 ... 65 535 | |
● Size, max. | 1 Mbyte | |
OB | ||
● Size, max. | 1 Mbyte | |
● Number of free cycle OBs | 100 | |
● Number of time alarm OBs | 20 | |
● Number of delay alarm OBs | 20 | |
● Number of cyclic interrupt OBs | 20; with minimum OB 3x cycle of 100 µs | |
● Number of process alarm OBs | 50 | |
● Number of DPV1 alarm OBs | 3 | |
● Number of isochronous mode OBs | 3 | |
● Number of technology synchronous alarm OBs | 2 | |
● Number of startup OBs | 100 | |
● Number of asynchronous error OBs | 4 | |
● Number of synchronous error OBs | 2 | |
● Number of diagnostic alarm OBs | 1 | |
Nesting depth | ||
● per priority class | 24 | |
Counters, timers and their retentivity | ||
S7 counter | ||
● Number | 2 048 | |
Retentivity | ||
— adjustable | Yes | |
IEC counter | ||
● Number | Any (only limited by the main memory) | |
Retentivity | ||
— adjustable | Yes | |
S7 times | ||
● Number | 2 048 | |
Retentivity | ||
— adjustable | Yes | |
IEC timer | ||
● Number | Any (only limited by the main memory) | |
Retentivity | ||
— adjustable | Yes | |
Data areas and their retentivity | ||
Retentive data area (incl. timers, counters, flags), max. | 768 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 700 KB | |
Extended retentive data area (incl. timers, counters, flags), max. | 20 Mbyte; When using PS 6 0W 24/48/60 V DC HF | |
Flag | ||
● Size, max. | 16 kbyte | |
● Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte | |
Data blocks | ||
● Retentivity adjustable | Yes | |
● Retentivity preset | No | |
Local data | ||
● per priority class, max. | 64 kbyte; max. 16 KB per block | |
Address area | ||
Number of IO modules | 16 384; max. number of modules / submodules | |
I/O address area | ||
● Inputs | 32 kbyte; All inputs are in the process image | |
● Outputs | 32 kbyte; All outputs are in the process image | |
per integrated IO subsystem | ||
— Inputs (volume) | 32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4 | |
— Outputs (volume) | 32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4 | |
per CM/CP | ||
— Inputs (volume) | 8 kbyte | |
— Outputs (volume) | 8 kbyte | |
Subprocess images | ||
● Number of subprocess images, max. | 32 | |
Hardware configuration | ||
Number of distributed IO systems | 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) | |
Number of DP masters | ||
● integrated | 1 | |
● Via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total | |
Number of IO Controllers | ||
● integrated | 2 | |
● Via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total | |
Rack | ||
● Modules per rack, max. | 32; CPU + 31 modules | |
PtP CM | ||
● Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots | |
Time of day | ||
Clock | ||
● Type | Hardware clock | |
● Backup time | 6 wk; At 40 °C ambient temperature, typically | |
● Deviation per day, max. | 10 s; Typ.: 2 s | |
Operating hours counter | ||
● Number | 16 | |
Clock synchronization | ||
● supported | Yes | |
● to DP, master | Yes | |
● in AS, master | Yes | |
● in AS, slave | Yes | |
● on Ethernet via NTP | Yes | |
Interfaces | ||
Number of PROFINET interfaces | 3 | |
Number of PROFIBUS interfaces | 1 | |
1. Interface | ||
Interface types | ||
● RJ 45 (Ethernet) | Yes; X1 | |
● Number of ports | 2 | |
● integrated switch | Yes | |
Protocols | ||
● IP protocol | Yes; IPv4 | |
● PROFINET IO Controller | Yes | |
● PROFINET IO Device | Yes | |
● SIMATIC communication | Yes | |
● Open IE communication | Yes; Optionally also encrypted | |
● Web server | Yes | |
● Media redundancy | Yes | |
PROFINET IO Controller | ||
Services | ||
— PG/OP communication | Yes | |
— Isochronous mode | Yes | |
— Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) | |
— IRT | Yes | |
— PROFIenergy | Yes; per user program | |
— Prioritized startup | Yes; Max. 32 PROFINET devices | |
— Number of connectable IO Devices, max. | 512; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET | |
— Of which IO devices with IRT, max. | 64 | |
— Number of connectable IO Devices for RT, max. | 512 | |
— of which in line, max. | 512 | |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces |
![]() |
SIEMENS 6ES7518-4AP00-3AB0 PROFINET RT, 3RD INTERFACE: PROFINET BASIC SERVICES, 4TH INTERFACE: PROFIBUS Images |